Interfaces | Microsemiconductor | Semiconductor | Conductor | Macro Conductor | Micro Conductor | Electrical Parts | American Microsemiconductor | Circuits | Transistor | Diode | Digital | Analog | Micro Controler | Electrical Conductor | Electrical Interfaces | AMS | IC | CMOS | NMOS | Silicon Transistor | Microprocessor | Processing | Integrated Circuits

| Power Components 6 SCRs in inverse parallel pairs for full phase angle soft start control 1600V PIV rating on all units RC snubber for dv/dt protection of each SCR pair | Jog Dry contact closure selects a non-ramping Jog function at an adjustable torque |
| Line Voltage Range 200 to 600 VAC, 3 phase +10% -15% on all units, 50/60Hz | Kick Start 10 - 100% starting torque for 0.1 - 2 seconds |
| Current Ratings 18 - 1250A depending on unit selection Range of each unit is 50-100% of maximum | Pump-Flex™ Deceleration Ramp Fully adjustable to match field conditions: Begin Decel setting, 0 - 100% of line voltage Decel ramp time, 1 - 60 seconds End Decel setting (Off ), 0 - 1% of Begin setting |
| AC Supply Voltage User supplied 120VAC +10% -15% tolerance, 60Hz Optional 240VAC 50Hz control available | Restart Delay Timer (Sequential Start Delay) Programmable time delay 1 - 999 seconds after loss of control power for staggered restarts |
| Overload Capacity (% of motor FLA) Standard Duty: 350% for 30 seconds, 1.0 SF Heavy Duty: 500% for 30 seconds, 1.15 SF | Time Clock Controller 24 hour/7 day time clock to provide automatic start Up to 7 start events per day Select operation from 1 through 7 days per week Run time determined by process control timer |
| Bypass Contactor Standard on all units Standard Duty: Shunt rated bypass Heavy Duty (Across-the-Line) line start rated bypass | Process Control Timer (choice of either) Permissive Run Timer 1- 999 minutes |
| Start/Stop Control Choices 2-wire Run-Stop using dry contacts 3-wire Start/Stop with built-in seal in contact N.C. Interlock input (dry contact) for remote devices | RS-485 Serial Communications Up to 247 starters per link Modbus RTU protocol built-in Full programming over the serial link Programmable remote starter control |
| Ramp Control Choices (4 built-in) Voltage Ramp Voltage Ramp with Current Limit CLT© Closed Loop Torque Ramp (Current Ramp) Current Step (current limit only) Ramp times adjustable 1 - 120 seconds Current Limit adjustable 200 - 600% of FLA | Operator Interface Tactile feedback keypad Easy to read LED display Run and fault status indicators |
| Dual Ramps Select via dry contact closure between any combinations of the above | Electronic Shear Pin Protection Trip level: 100 - 300% of motor FLA with trip delay |
| Start & Run Protection Two programmable overload trip curves allow for the thermal capacity required to start the load while providing motor overload protection needed during the run time. Start: Programmable for Class 5 - 30 Run: Programmable for Class 5 - 30, enabled when starter detects motor is "At-Speed" Reset: Manual or automatic, selectable via programming. Remote reset available. | Motor Duty Cycle Protection Back-spin/coast-down, starts-per-hour or minimum time between starts lockouts. Restart delay after a power failure. |
| Real-Time Thermal Modeling Continuously calculates motor operating temperature even when the motor is not running. | Short Circuit Trips at 10x unit current rating during run. Checks for shorted load prior to each start. |
| Retentive Thermal Memory Remembers the thermal condition of the motor even in the event of a power brown-out or black-out when power is restored. Extrapolates motor temperature using a real-time clock. | Shorted SCR Locks out on any single shorted SCR (defeatable) or can provide shunt trip function if multiple SCRs short or bypass contactor is welded closed. |
| Dynamic Reset Capacity Overload will not reset until thermal capacity in the motor is sufficient for a successful restart. Starter learns and retains this information from previous starts. | Metering Monitors phase current, ground current and motor thermal capacity. |
| Motor Temperature PTC thermistor input can also be used for E-stop or external overload relay. | Phase Loss Trips on phase current or voltage loss |
| Equipment Ground Fault Residual current method with adjustable trip delay. | Phase Rotation Phase rotation trip can be set to A-B-C, A-C-B or disabled. |
We consider 2 types of "Installation Contactors" for different applications : "Normal " Installation and "Day-Night" Installation. They are essentially used in automated building equipment, industry and offices for terminal circuit controlling less than 40 kW AC-1 (incandescent lamps, fluorescent lamps, convectors heating, batteries, regulation systems, ovens, drying systems), small motors controlling less than 15 kW AC-3 (ventilation, air conditioning, pumping, watering, automatic systems) and unbalasting systems in energy management (possibly enslavement from clocks, unballasting relays, telebreakers, thermostats).